INTERMEDIATE HEAT EXCHANGER
Main characteristics:
| Tube diameter x wall thickness |
21 x 1.4 mm |
| Tube length between tube-plates |
7.35 m |
| Number of tubes |
846 |
| Diameter of central tube |
460 mm |
| Vessel diameter |
1357 mm |
| Overall height |
11.6 m |
| Nozzle diameter |
300 mm |
| |
|
| Capacity |
85 MWth |
| Primary outlet temperature |
375 oC |
| Primary inlet temperature |
546 oC |
| Primary flow |
392.6 kg/s |
| Secondary inlet temperature |
335 oC |
| Secondary outlet temperature |
520 oC |
| Secondary flow |
362.5 kg/s |
| Working pressure on primary side |
11.2 bar |
| Working pressure on secondary side |
11.8 bar |
| Construction material |
Austenetic steel 1.4948 |